Auma Ex proof multi-turn actuator type: SAEX 07.6-13546782 Ex proof multi-turn actuator type: SAEX 07.6 ¦¦ Voltage: 3ph/380V/50Hz Duty: S2-15min short-time duty, classes A and B acc. to EN 15714-2 Valve attachment: F10 ¦¦ B3 ¦¦ 60 Nm ¦¦ 45 min⁻¹ ¦¦ 13,3 s Technical data sheet TR 22-0783 Pos.1 C.ref.: COM NO : 13
Auma Ex proof multi-turn actuator type: SAEX 07.6-13546782
Ex proof multi-turn actuator type: SAEX 07.6 ¦¦ Voltage: 3ph/380V/50Hz
Duty: S2-15min short-time duty, classes A and B acc. to EN 15714-2
Valve attachment: F10 ¦¦ B3 ¦¦ 60 Nm ¦¦ 45 min⁻¹ ¦¦ 13,3 s
Technical data sheet TR 22-0783 Pos.1 C.ref.: COM NO : 13546782 Code: SAEX07.6-F10-B3-45-Ex de IIC T4-3ph/380V/50Hz-S2-15min-KS-A0001-6.2-8.2-11.-24-22.01-10.1-21.4- V∙XX∙03-EX-1K-F (IEC 85)-KT∙105 (Ex e)-N∙30∙40-IP68 Wiring diagram: Standard Valve attachment: F10 ¦¦ B3 ¦¦ 60 Nm ¦¦ 45 min⁻¹ ¦¦ 13,3 s Settings: 60 Nm [ 60 Nm ] ¦¦ 10 U/Hub [ 10 turns/stroke ] Comment: - Actuator design description: SAEX07.6 Ex proof multi-turn actuator S2-15min short-time duty, classes A and B acc. to EN 15714-2 B3 output drive: bore with 1 keyway (acc. to EN ISO 5210) ø d10 = 20 mm ( 20 ) Ex de IIC T4 explosion protection: acc. to ATEX II2G, IEC, CIS directive, Zone 1 (gas) 3ph/380V/50Hz mains voltage: three-phase AC 380 V 50 Hz KS corrosion protection: KS is suitable for units occasionally or permanently exposed to aggressive chemical substances, average total film thickness 140 μm A0001 colour: finish painting with standard colour for corrosion protection KN/KS/KX (AUMA silver-grey similar RAL7037) 6.2 torque switching: tandem switches (2NC and 2NO) for each direction, switches galvanically isolated 8.2 limit switching: tandem switches (2NC and 2NO) for each end position, switches galvanically isolated 10.1 reduction gearing with fixed reduction 11. position indication: mechanical position indicator 21.4 remote position indication: position transmitter RWG 0/4-20 mA, 4 wire 24 blinker: blinker contact for running indication 22.01 heater: in switch compartment 110 V-250 V AC/DC V∙XX∙03-EX cable glands: qty. 3, IP68, Ms/Ni, EMV, EEx e 1K motor protection: PTC thermistors (according DIN 44082) F (IEC 85) motor winding insulation: insulation class F, tropicalized (IEC 85) KT∙105 (Ex e) ex-plug/socket connector KT (Ex e), cable entries with M-threads 1 x M20 x 1.5 / 1 x M25 x 1.5 / 1 x M32 x 1.5 N∙30∙40 temperature design: suitable for ambient temperature -30 °C to +40 °C IP68 enclosure protection IP68, submersible for max. 96 hours, max. 8 m head of water, up to 10 operations during the flooding Weight / Unit: 2
Muhtemelen patlayıcı ortamların ortaya çıkabileceği tesislerde patlama korumalı cihazların kullanılması şarttır. Bu cihazlar bir ateşleme kaynağına dönüşmeyecek şekilde tasarlanır. Yanıcı kıvılcımlar ve sıcak yüzey ısıları oluşturmazlar.
Sertifikasyon ulusal ve uluslararası sertifikasyon kurumları ile işbirliği içerisinde uygulanır.
SAEx/SAREx 07.2 - 16.2 çok turlu aktüatörleri ve SQEx/SQREx 05.2 - 14.2 kısmi turlu aktüatörleri için AUMATIC ACExC ile entegre lokal kumandalı bir kontrol ünitesi mevcuttur
Konstrüksiyon özellikleri
Interface ve işlev özellikleri
Onaylar
Çevre koşulları
Arabirimler