9,8 €

JB-750 grey 4 G 10 mm² Item No. 11130   Item No. 11130 Item description JB-750 grey 4 G 10 mm² Outer Ø mm (approx.) 18.2 AWG (approx.) 8 Cu-weight kg/km 384.0 Weight kg/km (approx.) 701.0 Copper base in EUR / 100 kg 150 VPE/m 500,1000 Cut-to-length service available yes EAN/GTIN 4060892006708 Customs tariff

JB-750 grey 4 G 10 mm²

Item No. 11130

 

Item No.

11130

Item description

JB-750 grey 4 G 10 mm²

Outer Ø mm (approx.)

18.2

AWG (approx.)

8

Cu-weight kg/km

384.0

Weight kg/km (approx.)

701.0

Copper base in EUR / 100 kg

150

VPE/m

500,1000

Cut-to-length service available

yes

EAN/GTIN

4060892006708

Customs tariff number

85444995

Technical Data

PVC control and connection cable in alignment with DIN VDE 0285-525-2-11 / DIN EN 50525-2-11
Temperature range flexible -15°C to +80°C
fixed -40°C to +80°C
Nominal voltage AC U0/U 450/750 V
fixed and protected installation AC U0/U 600/1000 V
Test voltage core/core 4000 V
Breakdown voltage 8000 V
Minimum bending radius flexible 7.5x Outer-Ø
fixed 4x Outer-Ø

Details

Cable Structure

  •  Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
  •  Core insulation: PVC acc. to DIN VDE 0207-363-3 / DIN EN 50363-3 (compound type TI2)
  •  Core identification acc. to JB/OB colour code, colour coded
  •  Protective conductor: starting with 3 cores,
  • G = with protective conductor GN-YE, in the outer layer,
  • X = without protective conductor (OB)
  •  Cores stranded in layers with optimal lay lengths
  •  Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 / DIN EN 50363-4-1 (compound type TM2)
  •  Sheath colour: grey (RAL 7001)
  •  Length marking: in metres

Properties

  •  largely resistant to: oil,
  • for details, see "Technical Information"
  •  the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers

Tests

  •  flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2

Notes

  •  the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
  •  cleanroom qualification tested on analog types; please note "cleanroom qualification" in your order

Application

  • Used for flexible applications involving medium mechanical stress with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use as a connection and control cable in machine tools, assembly lines, conveyor belts, production lines, plant construction, heating and air-conditioning technology, power plants, smelters and steel mills.