Lütfen Bekleyin

Pepperl+Fuchs Vibracon LVL-A7-LVL-A7-BG4B-E5PU-CG..EMS-275573-100030

Fiyat

249 €

Pepperl+Fuchs Vibracon LVL-A7-LVL-A7-BG4B-E5PU-CG..EMS-275573-100030      Vibration Limit Switch LVL-A7 Limit switch for liquids Onsite function check possible thanks to LED indication Large selection of process connections for hassle-free installation in existing systems Easy to install even at points difficult to access due to compact design Rugged stain

Pepperl+Fuchs Vibracon LVL-A7-LVL-A7-BG4B-E5PU-CG..EMS-275573-100030 

 

 

Vibration Limit Switch LVL-A7

  • Limit switch for liquids
  • Onsite function check possible thanks to LED indication
  • Large selection of process connections for hassle-free installation in existing systems
  • Easy to install even at points difficult to access due to compact design
  • Rugged stainless steel housing
  • Cost-saving plug connections
  • Approval as overfill protection and leak detection system acc. to WHG
General specifications
Measuring method The tuning fork is brought to its resonance frequency by means of a piezoelectric drive. If the tuning fork is covered by liquid, this frequency changes. The electronics monitor the resonance frequency and indicate whether the tuning fork is freely vibrating or is covered by liquid.
Construction type compact device
device with short tube
Operating mode MAX = maximum safety:
The device keeps the electronic switch closed as long as the liquid level is below the fork.
example application: overspill protection
MIN = minimum safety:
The device keeps the electronic switch closed as long as the fork is immersed in liquid.
example application: dry running protection of pumps
The electronic switch opens if the limit is reached, if a fault occurs or in the event of a power fails (quiescent current principle)
Series Vibracon LVL-A7
Supply
Rated voltage - DC-PNP: 10 ... 35 V DC, 3-wire
- AC/DC: 20 ... 253 V AC/DC, 2-wire
Current consumption - DC-PNP: < 15 mA
- AC/DC: < 3.8 mA
Power consumption - DC-PNP: < 975 mW
- AC/DC: < 850 mW
Input
Measured variable density
Measurement range min. 0.7 g/cm3, optional> 0.5 g/cm3
Output
Output type switch output
Switching current max. 250 mA
Directive conformity
Electromagnetic compatibility  
  Directive 2014/30/EU EN 61326-1:2006 , EN 61326-2-3:2006
Low voltage  
  Directive 2014/35/EU EN 61010-1:2010
Conformity
Electromagnetic compatibility NE 21
Degree of protection IEC 60529
Shock resistance EN 60068-2-27
Vibration resistance EN 60068-2-64
Climate class DIN EN 60068-2-38/IEC 68-2-38
Measurement accuracy
Reference operating conditions - ambient temperature: 25 °C (+77 °F)
- process pressure: 1 bar (14.5 psi)
- fluid: water (density: approx. 1 g/cm3, viscosity: 1 mm2/s)
- medium temperature: 25 °C (+77 °F)
- density setting: > 0.7 g/cm3
- switching time delay: standard (0,5 s, 1 s)
Measured value resolution < 0.5 mm
Measuring frequency approx. 1100 Hz in air
Switching point 13 mm ± 1 mm
Non-repeatability ± 1 mm acc. to DIN 61298-2
Hysteresis max. 3 mm
Influence of ambient temperature negligible
Influence of medium temperature -25 µm/°C
Influence of medium pressure -20 µm/bar
Switching time - 0.5 s when tuning fork is covered
- 1.0 s when tuning fork is uncovered
- other switching times on request
Operating conditions
Installation conditions  
  Installation position see section mounting position
Ambient conditions  
  Ambient temperature -40 ... 70 °C (-40 ... 158 °F)
  Storage temperature -40 ... 85 °C (-40 ... 185 °F)
  Shock resistance a = 300 m/s2 = 30 g, 3 planes x 2 directions x 3 shocks x 18 ms, as per test Ea
  Vibration resistance a(RMS) = 50 m/s2, ASD = 1.25 (m/s2)2/Hz, f = 5 to 2000 Hz, t = 3 x 2 h
Process conditions  
  Process temperature -40 ... +100 °C (-40 ... +212 °F)
-40 ... +150 °C (-40 ... +302 °F)
  Process pressure (static pressure) -1 ... +40 bar (-14.5 ... +580 psi)
  State of aggregation liquid
  Density min. 0.7 g/cm3, optional> 0.5 g/cm3
  Viscosity 1 ... 10000 mPa/s, dynamic viscosity
  Solid contents < ∅5 mm
Mechanical specifications
Degree of protection - IP65/67, NEMA 4X enclosure (plug M12)
- IP65, NEMA 4X enclosure (valve plug)
- IP65/68, NEMA 4X/6P enclosure (cable)
Connection - cable 5 m
- valve plug NPT1/2
- valve plug QUICKON
- valve plug M16
- plug M12
Material see technical information (TI)
Surface quality Ra < 3.2 µm
Mass see technical information (TI)
Dimensions see technical information (TI)
Process connection - thread ISO 228 G1/2, G3/4, G1
- thread EN 10226 R1/2, R3/4, R1
- thread ASME MNPT1/2, MNPT3/4, MNPT1
Indication and operation
Display elements The LED display is on the connection side.
- green LED: indication of ready to operate
- red LED: fault indication
- yellow LED: operating mode indication
Function test function test with test magnet (optional accessory)
Certificates and approvals
Overspill protection Z-65.11-554 (overspill protection acc. to WHG)
Z-65.40-555 (leak detection system acc. to WHG)
If you need the approvals also in paper form, select the option WH in the type code.
General information
Supplementary documentation technical information (TI)
manual (BA)
approval (ZE)
Supplementary information Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Accessories
Designation see technical information (TI)

 

Classifications

System Classcode
ECLASS 11.0 27200518
ECLASS 10.0.1 27200518
ECLASS 9.0 27200589
ECLASS 8.0 27200589
ECLASS 5.1 27200589
ETIM 8.0 EC001447
ETIM 7.0 EC001447
ETIM 6.0 EC001447